ADL-ÜSS Overvoltage protection
Three-level protection for 10 signal wires
The ADL-ÜSS protects its sensitive measuring technology from damage.
It has no influence on the measuring signal.
It can protect up to 10 signal wires.
Since there are no series resistors are suitable
it is for all analog signals.
Also for the resistance measurement as with
PT100, the module is ideally suited.
Advantages and functions
With common reference potential and separate GND / PE connection.
Technical specifications
Nominal voltage: | 24V DC |
---|---|
Highest continuous voltage: | < 25V DC |
Current Rating: | 1A |
Mode of operation: | Line-Earth Ground |
Operating temperature range: | -25°C ... 60°C |
Operating humidity range: | 0 ... 95 %rF not condensing |
protection: | IP 20 according to DIN 40 050-9/5.93 |
Case: | Polycarbonat |
Dimensions (L/W/H): | 90x50x36 mm |
Mounting: | Mounting on DIN-EN mounting rail |
Shop-Link: ADL-ÜSS
ADL-TMK
Temperature string
The ADL-TMK ® temperature string is used to measure temperature in
multiple depths of soil or water. The temperature string is also
used in thermal systems as well as in the monitoring of mining and buildings.
The string can be manufactured very flexible in length from a few meters up to
several hundred meters. The segmentation of the sensor modules can be done on
customer request.Up to 1000 meters long. The string can remain permanently
in the environment to be measured. Connection via 2-wire RS485 bus with
open vendor-independent Modbus-RTU protocol.
Up to 253 ADL-TMK® modules on one bus.
Advantages and functions
- Flexible string up to 1000 meters in length (other lengths on demand)
- Segmentation of the sensor modules can be done on customer request
- More cost-effective than fiber optic temperature measurement, because the string can remain permanently in the environment to be measured
- Long cable lengths possible via 2-wire RS485 bus
- open vendor-independent Modbus-RTU protocol
- Up to 253 ADL-TMK® modules can be connected to each bus or string
Wiring
- Highly flexible, durable and waterproof cable
- 4x 0.5 - 4 x 1.5 mm2 depending on the application
Communication
- 2-wire RS485 Bus
- Up to 253 modules are addressable on one bus
- Modbus-RTU protocol, 19200 baud, 8n1, addresses 1-253
- Cable lengths up to 1000 meters possible
Technical data temperature sensor
Sensors per module: | 1 sensor per module |
---|---|
Sensor type: | high-accuracy digital temperature sensor |
Resolution: | 0.0078K |
Accuracy: | ±0.1K (-20°C .. +50°C) |
Supply voltage: | 10 - 30VDC |
Power consumption: | less than 50mW per module |
Operating temperature: | -40°C .. +80°C |
Housing: | Polyolefin shrink tube and hotmolding potting |
Degree of protection: | IP 68 according to DIN 40 050-9/5.93 |
Dimensions: | ca. 100x12 mm |
Shop-Link: ADL-TMK
ADL-BTP
Soil temperature profile
Over the 6 measuring stages the soil temperature as well as the
Air temperature measured. The floor temperature profile sets the
Measured values directly into a digital RS485 bus signal.
Easy insertion of the ADL-BTP into the soil with minimal
Soil disturbance.
The ADL-BTP is a transmitter for determining the
Soil temperature in different depths.
The floor temperature profile is characterized by its simple
Handling and minimal ground failure during installation.
The measured values of the individual depth steps are directly in the sensor
detected by a temperature sensor embedded in the stainless steel ring,
converted to the Modbus RTU format and via the RS485 bus
provided.
Due to the white plastic, the sensor has a low
Self-heating on the surface and can therefore also the
Record air temperature near ground.
The floor temperature profile has a modular structure, thus
Individual lengths and measuring depths can be realized.
The sensor is suitable for the construction of RS485 bus systems
with different sensors up to a length of 1200m.
Technical specifications
Messbereich: | -30°C to +60°C |
---|---|
Accuracy: | ±0,2°C |
Resolution: | 0,0625°C |
Measuring depths: | +5cm, -5cm, -10cm, -20cm, -50cm, -100cm (standard version) |
Supply voltage: | 9 to 36VDC |
power consumption: | ~ 20mW |
Communication interface: | RS485 2- Draht (Standard 19200 Baud, 8n1) |
Communication protocol: | ModbusRTU |
Operating temperature range: | -40°C bis +80°C |
Housing material: | POM hollow bar (UV stabilized), stainless steel V4A |
Dimensions: | 1275 mm, Ø25 mm |
Sensor cable: | M12/5-pin plug, 5m cable |
protection: | IP67 |
Weight: | ca. 1,2 Kg |
optional: | individual lengths, measuring depths and measuring ranges on request |