ADL-FE FieldExtension
Outdoor extension
Suitable for hard outdoor use due to the high degree of protection IP67.
Extension of existing measuring systems by addressable bus system and
Cascadability of FieldExtension. The analogue measurements are taken from the
Data logger recorded via the RS485 interface. Universal use by
standardized M12 connections. Optimal for self-sufficient measuring stations by the
energy-saving design.
Advantages and functions
- easy extension of analog channels
- high degree of protection IP67 for outdoor use
- Addressable RS485 bus system
- the FieldExtension are cascadable
- Detecting different physical quantities (voltage, current, resistance, etc.)
- Each FieldExtension is connected via a standard M12 sensor / actuator cable
- the FieldExtension systems are optimized for low power operation
Technical specifications
Typ | L2010.1000 | L2010.2000 | L2010.3000 | L2010.5000 | L2010.6000 | L2010.7000 |
type description | ADL-FE_V2 | ADL-FE_V2 | ADL-FE_V2 | ADL-FE_V2 | ADL-FE_V2 | ADL-FE_V2 |
---|---|---|---|---|---|---|
PT100 | AD | AS | SF | M_4-20mA | M_50k | |
Supply Voltage Range | 9 - 36 VDC | |||||
power consumption (without sensors) |
< 120mW | < 180mW | < 180mW | < 135mW | < 180mW | < 180mW |
inputs | 5 | 5 | 6 | 2 | 5 | 5 |
resolution | 16 Bit | |||||
operating temperature range | -30 - 60°C | |||||
operating humidity range | 0-100%rF | |||||
settling time after switching on | 5 seconds | |||||
communication Interface | Modbus RTU - 19200 Baud, 8n1 | |||||
measuring range * | -40 - 60°C | 0 - 10VDC | 0 - 10VDC | 0 - 1200µVDC | 0 - 25mA | 0 - 50kOhm |
connection method | 4- wire | differential | ground based | differential | 2- wire | 4- Wire |
connection | Sensor / actuator cable M12 5-pin, A-coded | |||||
housing material | PVC housing | |||||
protection | IP 64 according to DIN 40 050-9/5.93 | |||||
weight | 325g | |||||
dimensions (L / W / H) | 190x60x50 |
* optional other measuring ranges possible
Explanation IP 64 DIN 40 050-9 / 5.93
Foreign body protection IP6x -> Protection against dust ingress (dustproof), complete protection against contact
Water protection IPx4 -> Protection against splashing water from all directions
ADL-MXSpro®
Multifunctional solar data logger
Via three RS485 interfaces, measured values of inverters, counters,
Network analyzers and transducers are recorded and stored.
Furthermore, the datalogger has an Ethernet interface for configuration via
the integrated web server and a USB interface
for data backup, memory expansion and connection of sensors or extensions.
For easy configuration and display of the current measured values are used
GLC display and four capacitive buttons.
Optionally, the datalogger has an integrated LTE modem.
Advantages and function
- Free choice of the provider for the web portal connection
- Support a variety of inverter manufacturers
- Online display of measured values on the device via a GLC display
- Graphical data visualization via web frontend
- Easy operation via capacitive buttons
- Easy configuration via web frontend (no additional software required)
- Data output in CSV or XML format
- Simple data storage extension via USB stick
- Optional internal GSM / LTE module
- Data transmission via e-mail / FTP
- Alerting via SMS and e-mail
Interface
- 3x RS485 interfaces (300 - 115200 baud)
- 1x SDI-12
- 1x RS232 V.24 (RXD / TXD / GND)
- 8x digital inputs / outputs
- (Status or 32bit counting input, switching output)
- 1x Ethernet interface (10 / 100MBit)
- 1x USB host (high-speed USB 2.0)
- Optionally with LTE modem
- extensions:
- CAN-Bus module
- Analogm input module
- Analog output module
Protocol
- Supported manufacturers can be found on our website
Inverter protocol
Technical specifications
Display: | GLC-Display 128 x 32 Pixel |
---|---|
Storage: | interner Datenspeicher auf SD Karte (Standard 1GB) |
Measurement memory rhythm: | 1 second - 24 hours |
Operating voltage: | 10 - 36VDC |
power consumption: | |
- Power saving mode: | 0,10W (12V, 8,3mA typ.) |
- Sampling rate of 5 min: | 0,11W (12V, 9,3mA typ.) |
- Sampling rate of 1 min: | 0,16W (12V, 13,3mA typ.) |
- Sampling rate of 10 s: | 0,76W (12V, 64mA typ.) |
- Maximum: | 1,80W (12V, 150mA typ.) |
Digital inputs / outputs: | |
- inputs: | max. 30VDC, 1[High]:>4VDC, 0[Low]: <1.6VDC, max. Counting frequency 2kHz |
- outputs: | max. 30VDC, max. 100mA, Open-Drain (high side, +VCC) |
Operating temperature range: | -20 to +70°C |
Operating humidity range: | 0 to 70 % rF (not condensing) |
Case: | Plastic, mounting on DIN EN rail |
protection: | IP 20 to DIN 40 050-9/5.93 |
Wight: | 250g (without antenna) |
Dimensions (L / W / H): | 107 x 90 x 60 mm |
Shop-Link: ADL-MXSpro
ADL-SR®
Solar meter - the irradiation sensor
The irradiation sensor determines the irradiance and gives the
momentary irradiation value in W / m². In addition, the sensor determines
Optionally the module temperature of solar panels. The analogue
The solar cell signal is converted to a digital RS485 signal in the sensor.
The sensors are individually calibrated and re-imported in Germany
ISO 9001 manufactured.
Advantages and functions
- each sensor is delivered with an individual calibration
- Addressable RS485 bus system
- Each bus can connect up to 253 sensors of different types
(Examples Sensors: Sun Sensor, Digital Inputs, Analog Inputs, etc.) - easy construction
- no loss of accuracy due to cable lengths
- Optionally, temperature and wind speed can be measured
Technical specifications:
Resolution: | 16 Bit |
---|---|
Measuring range radiation: | 0 to 1500 W/m² +/- 5 % |
Temperature sensor: | internal PT1000 1/3 DIN |
Measuring range temperature: | -30 °C to 70 °C +/- 1 °C |
Digital input: | Frequency measurement up to 1 kHz resolution 1 Hz |
Supply voltage: | 9 to 36 V DC / 260mW |
Operating temperature range: | - 30°C to 70°C |
Operating humidity range: | 0 to 100 %rF |
Communication interface: | Modbus RTU - 19200 Baud, 8n1 |
address 1 to 253 (delivery 2, 254 Broadcast) | |
Connection bus / supply: | plug M8 4-polig, A-coded |
Connection external sensors: | socket M8 4-polig, A-coded (for option with Y-dispatcher) |
Housing material: | Aluminium / PMMA Plexiglas |
protection: | IP 65 to DIN 40 050-9/5.93 |
Dimensions (L / W / H): | 150x130x20mm |
Weight: | 550g |
Option: | External temperature sensor PT1000 1/3 DIN |
Small Wind Transmitter (0,9 bis 40 m/s +/- 0,5 m/s ) |
Shop-Link: ADL-SR Sonnenmeter
parts for ADL-SR® Sonnenmeter
ADL-SR module temperature sensor PT1000 1/3 DIN self-adhesiveThis sensor measures the temperature of photovoltaic modules. The attachment is made by a large adhesive pad. This allows easy installation on the solar panel with very good heat transfer. The sensor is already assembled for connection to the ADL-SR sunmeter.
Temperature sensors: | PT1000 |
---|---|
Measuring range Temp.: | -35 to +105°C |
Measuring current: | ca. 1 mA |
Insulation resistance: | at 20°C and 500V DC, typ. 100 MOhm |
Cable: | PVC-Cable (2 x 0,25 mm²) |
Cable length: | Standard 2m (further on request) |
Circuit type: | 2-wire connection |
Stainless Steel Block: | stainless steel VA 1.4571 |
Dimension: | L 15 x B 8 x H 8mm, well Ø 5mm |
Protection: | IP54 |
Storage temperature: | -30 to +50°C |
Weight: | 77g |
Shop-Link: Modultemperaturfühler PT1000
ADL-SR Small Wind TransmitterRecord the wind speed directly at your system via the ADL-SR sunmeter. The wind speed can then be read out directly from the ADL-SR in "m / s" or recorded by the ADL-MXS datalogger. The small wind generator is connected directly to the ADL-SR. The plug is already assembled.
Transducer for measuring the horizontal wind speed in m / s.
Measuring range: | 0,5 - 40 m/s |
---|---|
Accuracy: | ±0,5 m/s bzw. ±5% v. reading |
Resolution: | 0,4 m wind path |
Electric output: | 0-100 Hz |
Load: | max. 60 m/s |
Contact load: | 10 VA, max. 42 VDC, max. 0,4 A |
Envi. Temperature: | -25 ... +60 °C |
Cable: | LiYY 2 x 0,5mm² |
Cable length: | Standard 3 m |
Dimension: | Ø 134 x 160 mm |
Protection: | IP54 |
Weight: | 0,3kg |
Shop-Link: Kleinwindgeber
ADL-MXSmini® - Solar Data Logger
Multifunctional datalogger system
Via three RS485 interfaces measured values of
Inverters, meters, network analyzers and transducers
be captured and stored. Furthermore, the datalogger has
via an Ethernet interface to the
Configuration via the integrated web server.
For easy configuration and display of the current measured values are used
GLC display and four capacitive buttons.
Optionally, the datalogger has an integrated GPRS modem.
Advantages and functions
- Free choice of the provider for the web portal connection
- Support a variety of inverter manufacturers
- Online display of measured values on the device via a GLC display
- Graphical data visualization via web frontend
- Easy operation via capacitive buttons
- Easy configuration via web frontend (no additional software required)
- Data output in CSV format
- Optional internal GPRS module
- Data transfer FTP
- Alerting via SMS and e-mail
Interfaces
- 2x RS485 external and 1x RS485 via backplane bus
- 1x counter input S0 (Open Collector)
- 1x Ethernet interface 10 / 100MBit
- 6x digital inputs (TTL level)
- 1x voltage output for external sensors (max 6W)
- 1x CAN bus (optional, via extension module)
- 1x GSM (optional)
Protocols
- Supported manufacturers can be found on our website
Inverter protocols
Technical specifications
Display: | GLC-Display 128 x 32 Pixel |
---|---|
Operating voltage: | 10 - 36VDC approx. 3.0W standard power supply 24V 1A (without external consumers) |
Operating temperature range: | - 20 to 70 °C |
Operating humidity range: | 0 to 70 % rF (not condensing) |
Housing material: | plastic |
protection: | IP 20 according to DIN 40 050-9/5.93 |
Weight: | 300 g |
Dimensions (L / W / H): | 107 x 90 x 60 mm |
Shop-Link: ADL-MXSmini